A) 1 and 2 only
B) 1 and 3 only
C) 1 and 4 only
D) 2 and 4 only
Correct Answer
verified
Multiple Choice
A) A list of all fluoroscopic procedures performed daily
B) A list of all radiographic procedures performed daily
C) Data pertinent to accumulated permanent equivalent dose to be placed on file
D) A report of all procedures performed when "on call" after regular hours
Correct Answer
verified
Multiple Choice
A) 1,2,and 3 only
B) 1,2,and 4 only
C) 1,2,and 5 only
D) 2,4,and 5 only
Correct Answer
verified
Multiple Choice
A) Geiger-Muller survey meter
B) Ionization chamber-type survey meter
C) Optically stimulated luminescence dosimeter
D) Proportional counter
Correct Answer
verified
Multiple Choice
A) 1 and 2 only
B) 1 and 3 only
C) 2 and 3 only
D) 1,2,and 3
Correct Answer
verified
Multiple Choice
A) 1,2,and 3 only
B) 1,2,and 4 only
C) 2,3,and 4 only
D) 1,2,3,and 4
Correct Answer
verified
Multiple Choice
A) electromagnetic force.
B) tiny electric currents with high precision and accuracy.
C) potential difference.
D) Voltage in an x-ray machine circuit.
Correct Answer
verified
Multiple Choice
A) universal serial bus (USB) .
B) charge-coupled device.
C) electrometer.
D) ionization chamber.
Correct Answer
verified
Multiple Choice
A) 1,2,and 3 only
B) 1,3,and 4 only
C) 2,3,and 5 only
D) 1,2,3,4,and 5
Correct Answer
verified
Multiple Choice
A) 1 only
B) 2 only
C) 3 only
D) 1,2,and 3
Correct Answer
verified
Multiple Choice
A) mistake has been made in recording the equivalent dose.
B) equivalent dose higher than the minimum measurable radiation quantity was recorded during that time.
C) equivalent dose below the minimum measurable radiation quantity was recorded during that time.
D) maximal equivalent dose has been exceeded during that time.
Correct Answer
verified
Multiple Choice
A) Pocket dosimeter
B) Proportional counter
C) Geiger-Muller survey meter
D) Ionization chamber-type survey meter
Correct Answer
verified
Multiple Choice
A) They must all be equally sensitive in the detection of ionizing radiation.
B) They should be able to detect all common types of ionizing radiation.
C) They should be calibrated annually to ensure accurate operation.
D) They should interact with ionizing radiation similarly to the way human tissue reacts.
Correct Answer
verified
Multiple Choice
A) densitometer.
B) ionization chamber.
C) thermoluminescent analyzer.
D) laser light at selected frequencies.
Correct Answer
verified
Multiple Choice
A) These devices are all used for area monitoring.
B) These devices all use the same sensing material to detect ionizing radiation.
C) These devices are all used for personnel monitoring.
D) Each of these devices can only be used for personnel monitoring for a maximum of 6 months.
Correct Answer
verified
Multiple Choice
A) Aluminum,tin,and copper
B) Aluminum,tin,and lead
C) Zinc,copper,and barium
D) Zinc,copper,and lead
Correct Answer
verified
Multiple Choice
A) Personnel digital ionization dosimeter
B) Optically stimulated luminescence dosimeter
C) Pocket ionization chamber
D) Thermoluminescent dosimeter
Correct Answer
verified
Multiple Choice
A) 1 hour
B) 1 week
C) 1 month
D) 3 months
Correct Answer
verified
Multiple Choice
A) may be color coded to facilitate correct usage and placement of the dosimeter on the body of occupationally exposed personnel.
B) must not have any type of printing on it.
C) must be radiopaque.
D) must never be exposed to ionizing radiation.
Correct Answer
verified
Multiple Choice
A) The shield covering the probe's sensitivity chamber
B) An audio amplifier and speaker
C) The metal that encloses the counter's gas-filled tube
D) The meter scale
Correct Answer
verified
Showing 1 - 20 of 25