Automatic tube compensation is active both during inspiration and expiration, and may reduce air trapping and _______________.

Correct Answer

verifed

verified

A negative pressure ventilator applies pressure inside the chest to expand it.

A) True
B) False

Correct Answer

verifed

verified

The ____ is the system that governs or controls the ventilator drive mechanism or output control valve.


A) solenoid valve
B) control circuit
C) compressor
D) piston

E) C) and D)
F) B) and D)

Correct Answer

verifed

verified

B

Which of the following waveforms are characteristically produced by ventilators having a rotary-driven piston drive mechanism?


A) rectangular
B) exponential
C) sinusoidal
D) oscillating

E) B) and C)
F) A) and B)

Correct Answer

verifed

verified

C

Discuss Robert Chatburn's ventilator classification system.

Correct Answer

verifed

verified

Robert Chatburn has proposed a new way t...

View Answer

Explain the advantage of both pressure-controlled ventilation and volume-controlled ventilation.

Correct Answer

verifed

verified

Pressure-controlled mode allows the clin...

View Answer

____ alarms alert the clinician to changes in oxygen concentration or gas temperature.


A) Expiratory gas
B) Volume
C) Inspiratory gas
D) Time

E) B) and C)
F) A) and B)

Correct Answer

verifed

verified

Describe the four types of flow waveforms.

Correct Answer

verifed

verified

The rectangular waveform is produced when volume is the control variable and the output is an ascending ramp. The flow waveform (a derivative of the volume waveform with respect to time), assumes the characteristic rectangular shape. The ramp waveform can be ascending or descending. If flow rises as the breath is delivered, it is termed ascending. If flow falls during the ventilator-supported breath, it is called a descending ramp. The sinusoidal waveform resembles the positive portion of a sine wave. It is generated by a rotary-driven piston drive mechanism.

The type of drive mechanism determines the characteristic flow and pressure patterns each ventilator produces.

A) True
B) False

Correct Answer

verifed

verified

Flow triggering has been shown to be more sensitive and responsive to a patient's efforts than pressure triggering.

A) True
B) False

Correct Answer

verifed

verified

_______________ proposed a new way to classify mechanical ventilators based on related features, physics, and engineering.

Correct Answer

verifed

verified

Robert Cha...

View Answer

_______________ alert the clinician to settings or parameters that are not within acceptable ranges or specifications, or they warn the clinician that the ventilator has failed some part of a self-diagnostic test.

Correct Answer

verifed

verified

Control ci...

View Answer

A ____ breath is initiated and delivered by the ventilator when it senses the patient's spontaneous inspiratory effort.


A) time-triggered
B) pressure-triggered
C) volume-triggered
D) flow-triggered

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

____ is defined as a change in volume divided by a change in pressure.


A) Flow
B) Compliance
C) Resistance
D) Pressure

E) B) and C)
F) A) and C)

Correct Answer

verifed

verified

Which of the following types of control circuits may also be referred to as servo controlled?


A) open loop
B) closed loop
C) mechanical
D) electronic

E) B) and D)
F) All of the above

Correct Answer

verifed

verified

A resistance load is proportional to ____.


A) volume
B) compliance
C) volume and airway resistance
D) airway resistance and inspiratory flow

E) C) and D)
F) None of the above

Correct Answer

verifed

verified

____ is a time-triggered, pressure-limited and time cycled mode that allows for spontaneous breathing.


A) Intermittent mandatory ventilation (IMV)
B) Automode
C) Proportional assist ventilation (PAV)
D) Airway pressure release ventilation (APRV)

E) None of the above
F) C) and D)

Correct Answer

verifed

verified

Which of the following flow waveforms is produced when volume is the control variable and the output is an ascending ramp?


A) rectangular
B) ascending ramp
C) descending ramp
D) sinusoidal

E) B) and D)
F) All of the above

Correct Answer

verifed

verified

____ are ventilators that measure and control inspiratory and expiratory time.


A) Flow controllers
B) Volume controllers
C) Pressure controllers
D) Time controllers

E) A) and D)
F) A) and C)

Correct Answer

verifed

verified

Describe inspiration and expiration.

Correct Answer

verifed

verified

During inspiration, the primary ventilat...