Filters
Question type

Study Flashcards

Power sources for Class 2 or Class 3 circuits may be derived from ________.


A) A listed or labeled Class 2 or Class 3 power supply or transformer
B) Any inherently limited power supply
C) Any power supply having a maximum output of 100VA
D) Any power supply 150V or less

E) All of the above
F) C) and D)

Correct Answer

verifed

verified

A Power-limited Class 1 circuit may operate at a maximum of _________.


A) 600V, 1000VA
B) 30V, 1000VA
C) 150V, 1000VA
D) 30V, 100VA

E) A) and D)
F) All of the above

Correct Answer

verifed

verified

Multiple Class 2 or Class 3 power supplies can be wired in parallel with each other.

A) True
B) False

Correct Answer

verifed

verified

False

Class 2 or Class 3 conductors may be installed within enclosures including electric light and power circuits provided _________.


A) The Class 2 and Class 3 circuits are installed as Class 3 and they maintain ¼" separation
B) They are installed as Class 1 circuits
C) The Class 1 circuits are functionally associated and maintain ¼' separation
D) All the above

E) All of the above
F) B) and D)

Correct Answer

verifed

verified

D

Class 2 or Class 3 audio circuit conductors in accordance with section 640.9 of the NEC, __________ occupy the same cable or raceway with other Class 2 or Class 3 remote control or signaling circuits.


A) Shall not be permitted to
B) Shall
C) Shall be permitted to
D) Must

E) A) and D)
F) All of the above

Correct Answer

verifed

verified

Class 3 power supplies may operate up to a maximum of 1000VA.

A) True
B) False

Correct Answer

verifed

verified

Class 1 circuits typically operate from greater voltage and current levels than those of Class 2 or 3 circuits.

A) True
B) False

Correct Answer

verifed

verified

Signaling circuits include _________.


A) Circuits that activate notification devices
B) Circuits that signal other circuits
C) Circuits that control other circuits
D) Communication circuits

E) All of the above
F) C) and D)

Correct Answer

verifed

verified

Class 2 or Class 3 conductors may be run in the same raceway with Class 1 circuits provided _________.


A) They are functionally associated
B) They are separated by a solid and firmly fixed barrier
C) That there is a 2 inch separation between the conductors
D) They are carrying less than 150V

E) C) and D)
F) A) and C)

Correct Answer

verifed

verified

B

If an equipment failure were to introduce a direct life or fire hazard, the circuit must be reclassified as Class 1.

A) True
B) False

Correct Answer

verifed

verified

Exterior run Class 2 and Class 3 circuits must maintain a minimum separation of _________ from Class 1 electric light and power circuits.


A) ¼ inch
B) 1 inch
C) 2 inch
D) 6 inch

E) B) and C)
F) A) and B)

Correct Answer

verifed

verified

You have a Rigid PVC conduit (RNC), schedule 80, that is required to hold the following conductors; six -18AWG TFN, ten -18AWG XFF and four -16AWG XF.   Answer the questions below. Calculate the total diameter of the XF conductors.

Correct Answer

verifed

verified

In elevators, power-limited circuits must be installed __________.


A) To maintain a 2 inch separation form class 1 circuits
B) Inside a rigid metal conduit or non-metallic conduit
C) As class 1 wiring
D) In a cable tray

E) None of the above
F) All of the above

Correct Answer

verifed

verified

Instrumentation tray cable can be used as a substitute for Class 3 wiring.

A) True
B) False

Correct Answer

verifed

verified

You have a Rigid PVC conduit (RNC), schedule 80, that is required to hold the following conductors; six -18AWG TFN, ten -18AWG XFF and four -16AWG XF.   Answer the questions below. What size RNC is needed to accommodate the conductors?

Correct Answer

verifed

verified

A power-limited Class 3 power supply must never exceed _________.


A) 30V, 100VA
B) 150V, 100VA
C) 300V, 100VA
D) 600V, 1000VA

E) None of the above
F) A) and B)

Correct Answer

verifed

verified

Class 1 circuits, that are not functionally associated, must be separated from power conductors by a solid and firmly fixed barrier.

A) True
B) False

Correct Answer

verifed

verified

Coaxial cable connecting a video camera to a monitor is an example of integral wiring.

A) True
B) False

Correct Answer

verifed

verified

The overcurrent protection device for a Class 1 circuits may be rated to _________.


A) 70% of the power supply rating
B) 100% of the power supply rating
C) 167% of the power supply rating
D) 200% of the power supply rating

E) C) and D)
F) All of the above

Correct Answer

verifed

verified

You have a Rigid PVC conduit (RNC), schedule 80, that is required to hold the following conductors; six -18AWG TFN, ten -18AWG XFF and four -16AWG XF.   Answer the questions below. ​ Calculate the total diameter of the XFF conductors.

Correct Answer

verifed

verified

Showing 1 - 20 of 30