Filters
Question type

When a ControlLogix module with an integrated USB port is being used for the first time with a particular computer, the required USB drivers must be configured.

A) True
B) False

Correct Answer

verifed

verified

If the switches of the 1756-EN2T are set for a specific address, this IP address can be changed in the module's configuration window in RSLinx.

A) True
B) False

Correct Answer

verifed

verified

If the USB driver is configured in conjunction with the USB port configuration of the personal computer, the driver cannot be reconfigured in ____________________.

Correct Answer

verifed

verified

RSLinx

List two examples of features supported by newer modular ControlLogix Ethernet/IP communications modules.

Correct Answer

verifed

verified

Examples of features supported by newer ...

View Answer

When a new device is connected to a personal computer, the Found New Hardware Wizard can assist with installing driver software automatically.

A) True
B) False

Correct Answer

verifed

verified

The three switches on top of the 1756-EN2T module can be modified before or after installing the module in a chassis.

A) True
B) False

Correct Answer

verifed

verified

List three points to keep in mind for using USB communications between a personal computer and a ControlLogix Communications Module.

Correct Answer

verifed

verified

Points to Keep in Mind for Using USB Com...

View Answer

If you have a personal computer with no standard serial port but with USB ports, and a ControlLogix controller with a traditional 9-pin D-shell serial port, direct serial communication between the personal computer and the ControlLogix controller will be very easy.

A) True
B) False

Correct Answer

verifed

verified

False

With the RSLinx driver configured, a RSLogix 5000 project can be downloaded from the personal computer to the ControlLogix controller by way of the 1756-EN2T's USB port.

A) True
B) False

Correct Answer

verifed

verified

To download an RSLogix project to a ControlLogix controller, the project must be saved and closed.

A) True
B) False

Correct Answer

verifed

verified

Typically, the personal computer USB driver configuration only has to be completed once.

A) True
B) False

Correct Answer

verifed

verified

In addition to using the three switches on top of the 1756-EN2T module to configure an IP address, what are two other methods by which the module's IP address can be configured?

Correct Answer

verifed

verified

In addition to using the three switches on top of the 1756-EN2T module to configure an IP address, the module's IP address can also be configured using RSLogix 5000 or RSLinx software.